Technical Properties
Architecture
![]() | Neutral position: | without neutral |
![]() | Number of protected poles: | 3 |
![]() | Number of poles: | 3 P |
![]() | Type of pole: | 3 P |
![]() | Fixing mode: | Din-Rail |
![]() | Curve: | D |
Compatibility
![]() | Compatible with DIN rail mounting: | yes |
Connectivity
![]() | Bottom connection alignement for modular devices: | Aligned terminal |
![]() | Top connection alignement for modular devices: | Aligned terminal |
Main electrical features
![]() | Type of supply voltage: | AC |
![]() | Rated operational voltage Ue: | 400 V |
Voltage
![]() | Minimum threshold voltage (Ue min): | 12 V |
![]() | Rated insulation voltage: | 500 V |
![]() | Rated impulse withstand voltage: | 6000 V |
Electric current
![]() | Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2: | 15 kA |
![]() | Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1: | 10 kA |
![]() | Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1: | 10 kA |
![]() | Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1: | 10 kA |
![]() | Rated short circuit breaking capacity Icn under 380V AC according IEC 60898-1: | 10 kA |
![]() | Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1: | 10 kA |
![]() | Rated service breaking capacity Ics AC according IEC 60898-1: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 220V AC according IEC 60947-2: | 15 kA |
![]() | Rated service breaking capacity Ics under 230V AC according IEC 60947-2: | 15 kA |
![]() | Rated service breaking capacity Ics under 240V AC according IEC 60947-2: | 15 kA |
![]() | Rated service breaking capacity Ics under 380V AC according IEC 60947-2: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 400V AC according IEC 60947-2: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 415V AC according IEC 60947-2: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 220V AC according IEC 60898-1: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 230V AC according IEC 60898-1: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 240V AC according IEC 60898-1: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 380V AC according IEC 60898-1: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 400V AC according IEC 60898-1: | 7,5 kA |
![]() | Rated service breaking capacity Ics under 415V AC according IEC 60898-1: | 7,5 kA |
![]() | Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2: | 30 kA |
![]() | Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2: | 30 kA |
![]() | Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2: | 30 kA |
![]() | Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2: | 15 kA |
![]() | Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2: | 15 kA |
![]() | Magnetic regulating currrent: | 10/14,4 In |
![]() | min/maxi threshold value of the DC magnetic operation: | 15/30 In |
![]() | min/maxi threshold value of the AC thermal operation: | 1,13/1,45 In |
![]() | min/maxi threshold value of the DC thermal operation: | 1,13/1,45 In |
Electric current / temperature
![]() | Rating current -15°C: | 23,98 A |
![]() | Rating current -20°C: | 24,38 A |
![]() | Rating current 0°C: | 22,73 A |
![]() | Rating current 10°C: | 21,86 A |
![]() | Rating current -10°C: | 23,57 A |
![]() | Rating current 25°C: | 20,48 A |
![]() | Rating current -25°C: | 24,78 A |
![]() | Rating current 30°C: | 20 A |
![]() | Rating current 35°C: | 19,48 A |
![]() | Rating current 40°C: | 18,94 A |
![]() | Rating current 45°C: | 18,39 A |
![]() | Rating current 5°C: | 22,3 A |
![]() | Rating current -5°C: | 23,16 A |
![]() | Rating current 50°C: | 17,81 A |
![]() | Rating current 55°C: | 17,22 A |
![]() | Rating current 60°C: | 16,61 A |
![]() | Rating current 65°C: | 15,98 A |
![]() | Rating current 70°C: | 15,32 A |
Current correction factors
![]() | Correction factor of magnetic tripping with 100 Hz: | 1,1 |
![]() | Correction factor of magnetic tripping with 200 Hz: | 1,2 |
![]() | Correction factor of magnetic tripping with 400 Hz: | 1,5 |
![]() | Correction factor of magnetic tripping with 60 Hz: | 1,1 |
![]() | Correction factor of rating current for 2 devices placed side-by-side: | 1 |
![]() | Correction factor of rating current for 3 devices placed side-by-side: | 0,95 |
![]() | Correction factor of rating current for 4 and 5 devices placed side-by-side: | 0,9 |
![]() | Correction factor of rating current for 6 devices placed side-by-side: | 0,85 |
Power
![]() | Power loss per pole at In: | 2,72 W |
![]() | Maximum power loss per pole according to the product standard: | 4,5 W |
![]() | Total power loss under IN: | 8,04 W |
Endurance
![]() | Electric endurance in number of cycles: | 4000 |
![]() | Number of mechanical operations: | 20000 |
Dimensions
![]() | Depth of installed product: | 70 mm |
![]() | Height of installed product: | 83 mm |
![]() | Width of installed product: | 52,5 mm |
Installation, mounting
![]() | Type of top connection for modular devices: | with screw |
![]() | Tightening torque: | 2,8Nm |
![]() | Type of bottom rail clip for modular devices: | plastic |
![]() | Type of top rail clip for modular devices: | NA |
![]() | Type of Bottom Connection for modular devices: | BIconnect |
![]() | Bottom removability for modular devices: | yes |
![]() | Top removability for modular devices: | yes |
![]() | Suitable for flush-mounting: | yes |
Connection
![]() | Upstream cage clamp delivery status: | opened |
![]() | Downstream cage clamp delivery status: | opened |
![]() | Connection cross-section at output with screw, for flexible conductor: | 1/25 mm² |
![]() | Connection cross-section of the access with screws, with flexible conductor: | 1/25 mm² |
![]() | Connection cross-section at output with screw, for massive conductor: | 1/35 mm² |
![]() | Connection cross-section for rigid conductor, upstream terminals with screws: | 1/35 mm² |
Equipment
![]() | Can be accessorized: | yes |
Standards
![]() | Standard text: | EN 60898-1, IEC 60947-2 |
![]() | European directive WEEE: | concerned |
Safety
![]() | Protection index IP: | IP20 |
Use conditions
![]() | Degree of pollution according to IEC 60664 / IEC 60947-2: | 2 |
![]() | Altitude: | 2000 m |
temperatur
![]() | Temperature of calibration: | 50 °C |
*All data is subject to errors and technical modifications. All prices are recommended retail prices.