Cat. Ref.:MSN350
EAN No.:3250613810177
ex. GST*:70,61 $ / pc.
inc. GST*:77,67 $ / pc.

Technical Properties

Architecture
Neutral position:without neutral
Number of protected poles:3
Number of poles:3 P
Type of pole:3 P
Fixing mode:DIN rail type O
(symmetrical)
Curve:C
Controls and indicators
With fault indicator:no
Connectivity
Bottom connection alignement for modular devices:Aligned terminal
Top connection alignement for modular devices:Aligned terminal
Main electrical features
Frequency:50/60 Hz
Rated short circuit breaking capacity Icn AC according IEC60898-1:6 kA
Type of supply voltage:AC
Rated operational voltage Ue:415 V
Voltage
Rated insulation voltage:500 V
Rated impulse withstand voltage:4000 V
Electric current
Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1:6 kA
Rated service breaking capacity Ics AC according IEC 60898-1:6 kA
Rated service breaking capacity Ics under 415V AC according IEC 60898-1:6 kA
Magnetic regulating currrent at 40° C:5/10 In
min/maxi threshold value of the AC thermal operation:1,13/1,45 In
Electric current / temperature
Rating current -15°C:60,23 A
Rating current -20°C:61,17 A
Rating current 0°C:57,41 A
Rating current 10°C:55,53 A
Rating current -10°C:59,27 A
Rating current 15°C:54,59 A
Rating current 20°C:53,65 A
Rating current 25°C:52,71 A
Rating current -25°C:62,1 A
Rating current 30°C:51,78 A
Rating current 35°C:50,84 A
Rating current 40°C:50 A
Rating current 45°C:48,96 A
Rating current 5°C:56,47 A
Rating current -5°C:58,35 A
Rating current 50°C:47,93 A
Rating current 55°C:47,08 A
Rating current 60°C:46,14 A
Rating current 65°C:45,2 A
Rating current 70°C:44,26 A
Current correction factors
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Power
Power loss per pole at In:6,4 W
Total power loss under IN:16,3 W
Endurance
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Dimensions
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:52,5 mm
Installation, mounting
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of bottom rail clip for modular devices:plastic
Type of Bottom Connection for modular devices:BIconnect
Bottom removability for modular devices:yes
Top removability for modular devices:no
Connection
Connection cross-sect. rigid cable:1 / 35mm²
Connection cross-sect. flexible conductor:1 / 25mm²
Type of connection:with screw
Connection cross section of access and exit with screws, for flexible conductor:1/25 mm²
Connection cross-section of input and output with screws, for massive conductors:1/35 mm²
Equipment
Can be accessorized:yes
Standards
Standard text:EN 60898-1, AS/NZS
60898-1
European directive WEEE:concerned
Safety
Protection index IP:IP20
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Class of energy limitation I²t:3
Altitude:2000 m
Storage temperature:-25 to 80 °C
Air humidity protection:for all climates

*All data is subject to errors and technical modifications. All prices are recommended retail prices.