Cat. Ref.:ADA913T
EAN No.:3250611011590
ex. GST*:124,21 $ / pc.
inc. GST*:136,63 $ / pc.

Technical Properties

Architecture
Neutral position:right
Number of protected poles:1
Number of poles:2 P
Type of pole:1P+N
Curve:C
Compatibility
Compatible with DIN rail mounting:yes
Controls and indicators
With fault indicator:yes
Main electrical features
Frequency:50 Hz
Rated short circuit breaking capacity Icn AC according IEC60898-1:6 kA
Rated operational voltage Ue:240 V
Voltage
Rated insulation voltage:500 V
Max operating voltage:240 V
Rated impulse withstand voltage:4000 V
Electric current
Rated residual operating current:30 mA
Withstand not tripping on 8-20 μs wave:250 A
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:6 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:6 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:6 kA
Breaking and opening capacity:6 kA
Magnetic regulating currrent at 40° C:5/10 In
min/maxi threshold value of the AC thermal operation:1,13/1,45 In
Electric current / temperature
Rating current -15°C:14,9 A
Rating current -20°C:15,1 A
Rating current 0°C:14,3 A
Rating current 10°C:13,9 A
Rating current -10°C:14,7 A
Rating current 15°C:13,7 A
Rating current 20°C:13,5 A
Rating current 25°C:13,2 A
Rating current -25°C:15,3 A
Rating current 30°C:13 A
Rating current 35°C:12,8 A
Rating current 40°C:12,6 A
Rating current 45°C:12,4 A
Rating current 5°C:14,1 A
Rating current -5°C:14,5 A
Rating current 50°C:12,2 A
Rating current 55°C:12 A
Rating current 60°C:11,8 A
Rating current 70°C:8,8 A
Current correction factors
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Selectivity
Minimal rating current of upstream aM fuse for selectivity on short-circuit:16 A
Minimal rating current of upstream gL fuse for selectivity on short-circuit:20 A
Maximal rating current of downstream aM fuse for selectivity on short-circuit:2 A
Maximal rating current of downstream gL fuse for selectivity on short-circuit:8 A
Power
Power loss per pole at In:3,3 W
Total power loss under IN:3,8 W
Tripping
Protected against nuisance tripping:no
Endurance
Electric endurance in number of cycles:2000
Number of mechanical operations:2000
Dimensions
Depth of installed product:68 mm
Height of installed product:83 mm
Width of installed product:35 mm
Installation, mounting
Type of bottom rail clip for modular devices:plastic
Bottom removability for modular devices:yes
Top removability for modular devices:no
Connection
Connection cross-section at output with screw, for flexible conductor:1/16 mm²
Connection cross-section of the access with screws, with flexible conductor:1/16 mm²
Connection cross-section at output with screw, for massive conductor:1/25 mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1/25 mm²
Connection cross-sect. rigid cable:1 / 25mm²
Connection cross-sect. flexible conductor:1 / 16mm²
Type of connection:with screw
Standards
Standard text:IEC 61009-1, AS/NZS
61009-1
European directive WEEE:not concerned
Safety
Protection index IP:IP20
Residual current type:A
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Class of energy limitation I²t:3
Altitude:2000 m
Storage temperature:-25 to 70 °C
Air humidity protection:for all climates
temperatur
Temperature of calibration:30 °C

*All data is subject to errors and technical modifications. All prices are recommended retail prices.