RCBO 1M 1P 10kA C-6A 10mA A

Cat. Ref.:AC106B
EAN No.:3250611013242
This product is not sold any longer.
This page, however, remains available for information ourposes.
Please contact your wholesaler in order to find appropriate follow-up products!

Technical Properties

Architecture
Neutral position:right
Number of protected poles:1
Number of poles:1 P
Type of pole:1 P
Fixing mode:Din-Rail
Curve:C
Functions
Concurrently switching N-neutral:no
Sealable:yes
Compatibility
Compatible with DIN rail mounting:yes
Controls and indicators
With fault indicator:no
Main electrical features
Rated short circuit breaking capacity Icn AC according IEC60898-1:10 kA
Rated operational voltage Ue:240 V
Frequency:50 Hz
Voltage
Rated insulation voltage:250 V
Max operating voltage:253 V
Rated impulse withstand voltage:4000 V
Electric current
Rated residual operating current:10 mA
Rated current:6 A
Withstand not tripping on 8-20 μs wave:3 kA
Breaking and opening capacity:6 kA
min/maxi threshold value of the AC thermal operation:1,13 / 1,45 In
Magnetic regulating currrent:5 / 10 In
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:10 kA
Electric current / temperature
Rating current -25°C:7,72 A
Rating current -20°C:7,58 A
Rating current -15°C:7,43 A
Rating current -10°C:7,29 A
Rating current -5°C:7,14 A
Rating current 0°C:6,99 A
Rating current 5°C:6,83 A
Rating current 10°C:6,67 A
Rating current 15°C:6,51 A
Rating current 20°C:6,35 A
Rating current 25°C:6,18 A
Rating current 30°C:6 A
Rating current 35°C:5,82 A
Rating current 40°C:5,63 A
Rating current 45°C:5,44 A
Rating current 50°C:5,24 A
Rating current 55°C:5,03 A
Rating current 60°C:4,81 A
Current correction factors
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Frequency
Frequency:50 Hz
Power
Total power loss under IN:1,5 W
Power loss per pole at In:1,24 W
Tripping
Protected against nuisance tripping:no
Endurance
Electric endurance in number of cycles:2000
Number of mechanical operations:1000
Dimensions
Depth of installed product:70 mm
Height of installed product:110 mm
Width of installed product:17,8 mm
Installation, mounting
Tightening torque:2,1Nm
Type of top rail clip for modular devices:NA
Type of bottom rail clip for modular devices:metallic isolated
Top removability for modular devices:no
Bottom removability for modular devices:no
360° product mounting position:yes
Connection
Connection cross-section at output with screw, for flexible conductor:1 / 16 mm²
Connection cross-section at output with screw, for massive conductor:1 / 25 mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1 / 25 mm²
Connection cross-section of the access with screws, with flexible conductor:1 / 16 mm²
Equipment
With transparent product label holder:no
Standards
Standard text:IEC 61009-1, AS/NZS
61009-1
European directive WEEE:concerned
Safety
Protection index IP:IP20
Residual current type:A
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Class of energy limitation I²t:3
Altitude:2000 m
Air humidity protection:Execution II